Hardware/Perc/MegaCli/BriefCommands

De TartareFR
Version datée du 20 juillet 2012 à 08:42 par Didier (discussion | contributions) (Page créée avec « = View information about the RAID adapter = == For checking the firmware version, battery back-up unit presence, installed cache memory and the capabilities of the adapter =... »)
(diff) ← Version précédente | Voir la version actuelle (diff) | Version suivante → (diff)
Aller à la navigation Aller à la recherche

View information about the RAID adapter

For checking the firmware version, battery back-up unit presence, installed cache memory and the capabilities of the adapter

# MegaCli64 -AdpAllInfo -aAll

View information about the battery backup-up unit state

# MegaCli64 -AdpBbuCmd -aAll

View information about virtual disks

Useful for checking RAID level, stripe size, cache policy and RAID state:

# MegaCli64 -LDInfo -Lall -aALL

View information about physical drives

# MegaCli64 -PDList -aALL

Patrol read

Patrol read is a feature which tries to discover disk error before it is too late and data is lost. By default it is done automatically (with a delay of 168 hours between different patrol reads) and will take up to 30% of IO resources.

To see information about the patrol read state and the delay between patrol read

# MegaCli64 -AdpPR -Info -aALL

To find out the current patrol read rate

# MegaCli64 -AdpGetProp PatrolReadRate -aALL

To reduce patrol read resource usage to 2% in order to minimize the performance impact

# MegaCli64 -AdpSetProp PatrolReadRate 2 -aALL

To disable automatic patrol read

# MegaCli64 -AdpPR -Dsbl -aALL

To start a manual patrol read scan

# MegaCli64 -AdpPR -Start -aALL

To stop a patrol read scan:

# MegaCli64 -AdpPR -Stop -aALL

You could use the above commands to run patrol read in off-peak times. Migrate from one RAID level to another

In this example, I migrate the virtual disk 0 from RAID level 6 to RAID 5, so that the disk space of one additional disk becomes available. The second command is used to make Linux detect the new size of the RAID disk.

# /usr/local/sbin/MegaCli64 -LDRecon -Start -r5 -L0 -a0
# echo 1 > /sys/block/sda/device/rescan

Create a new RAID 5 virtual disk from a set of new hard drives

First we need to now the enclosure and slot number of the hard drives we want to use for the new RAID disk. You can find them out by the first command. Then I add a virtual disk using RAID level 5, followed by the list of drives I want to use, specified by enclosure:slot syntax.

# MegaCli64 -PDList -aALL | egrep 'Adapter|Enclosure|Slot|Inquiry'
# MegaCli64 -CfgLdAdd -r5'[252:5,252:6,252:7]' -a0

View reconstruction progress

When reconstructing a RAID array, you can check its progress with this command.

# MegaCli64 -LDRecon ShowProg L0 -a0


Idea.png
replace L0 by L1 for the second virtual disk, and so on

Configure write-cache to be disabled when battery is broken

# MegaCli64 -LDSetProp NoCachedBadBBU -LALL -aALL

Change physical disk cache policy

If your system is not connected to a UPS, you should disable the physical disk cache in order to prevent data loss.

# MegaCli -LDGetProp -DskCache -LAll -aALL

To enable it (only do this if you have a UPS and redundant power supplies):

# MegaCli -LDGetProp -DskCache -LAll -aALL